Transformer Monitoring


How to Improve Transformer Protection

Using symmetrical components for fault discrimination in differential protection BY IMRAN RIZVI, ABB Inc. Classical differential protection schemes are subject to ghost differential currents due to current transformer (CT) saturation and magnetization currents. Several methods are used to counter...


Transient Analysis of Power Transformers Using Finite Element Method

A transformer relies on electromagnetic induction through coils to transfer electric energy between two or more circuits. Varying current in the transformer’s primary winding creates varying magnetic flux in the core, which produces varying electromotive force (EMF) or voltage in the...

Transformer Monitoring

Sweep Frequency Response Analysis

Sweep frequency response analysis: Reliable demagnetization of transformer cores

BY MARKUS PÜTTER, MICHAEL RÄDLER, BORIS UNTERER, OMICRON electronics GmbH

Whenever a power or distribution transformer is isolated from the power system, it is very probable that residual magnetism remains in the core due to the phase shift. However, residual magnetism also occurs when performing winding resistance tests. Since manufacturers use these measurements in their routine testing and these tests are typically performed for on-site condition...

Related Articles


Transient Analysis of Power Transformers Using Finite Element Method

A transformer relies on electromagnetic induction through coils to transfer electric energy between two or more circuits. Varying current in the transformer’s primary winding creates varying magnetic flux in the core, which produces varying electromotive force (EMF) or voltage in the...

Grounding Transformers Explained

By R. W. Hurst, Editor Grounding transformers are used to provide a path to ground for unbalanced load current and for fault currents on systems where a suitable ground is otherwise not available. Grounding transformers are normally constructed with one of the two configurations: Zig-Zag (Zn) with...

hydrocarbon gas emission

Advancements in Dissolved Gas Analysis: Risk Assessment

In general, the purpose of periodic screening with DGA for power transformers is risk assessment. Is any transformer likely to fail in service? If so, how severe is the problem? Previous articles in this series have described ways to improve DGA interpretation. In this article we provide a glimpse...