As the adoption of renewable energy technologies accelerates across the globe, the FBI has issued a stark warning about the increasing cyber risks associated with these advancements. The rise in renewable energy infrastructure, while crucial for achieving climate goals, has also attracted the attention of cybercriminals and adversaries seeking to exploit vulnerabilities in these systems. The FBI’s alert underscores the need for robust cybersecurity measures to protect critical energy infrastructure and ensure the stability of...

Popular T&D Articles


T&D Buyer's Guide


T&D News




Utility News

New York's Path to 8.5 GW of Grid Flexibility by 2040

New York State's transition to a clean, zero-emissions energy grid could include up to 8.5 gigawatts (GW) of grid flexibility by 2040, according to a new report from the Brattle Group. This projection, while contingent on achieving ambitious decarbonization goals, illustrates how the state could...

T&D Trends



Electrical Substations

Power Factor Testing of Circuit Breakers

Detecting contamination and deterioration in SF6 breakers to ensure longevity

BY LINDA NOWAK, Doble Engineering Company

The purpose of “Doble testing”, or power factor testing, SF6 (sulfur hexafluoride) circuit breakers is to detect the presence of contamination and/or deterioration of the breaker’s insulating system. This process will allow corrective actions to be taken to ensure the integrity of the breaker.

The Doble test is completed by measuring the insulation’s dielectric-loss and capacitance and calculating the power factor. The increase of the dielectric loss and, consequently, the power factor, is representative of an increase in contamination and/or deterioration of the insulating system. The Doble test can detect a number of problems including the following items.

• Moisture contamination resulting from leaks or incomplete cleaning and drying • Deterioration of line-to-ground and contact-grading capacitors • Surface contamination of weathersheds • Deterioration of insulating components such as operating rods,...