Transformer Testing & Maintenance
How to Improve Transformer Protection
Bringing Science to Transformer Risk Management
Transformer Testing & Maintenance
Hydrogen Monitoring in the Transformer Headspace Compared to Traditional In-Oil Monitoring
By Chris Rutledge, Product Manager, Dynamic Ratings, Inc.
Introduction
The utilization of online dissolved gas analysis monitoring has proven to be one of the most effective predictors of overall transformer health and condition. A wide range of monitoring systems are available, offering multiple cost/feature/benefit combinations.
Hydrogen Monitoring
Single or key gas monitoring relies on the use of a sensor for the detection of hydrogen levels either dissolved in the oil or...
Related Articles
Bringing Science to Transformer Risk Management
Reliability-based Dissolved Gas Analysis is a new methodology that provides the most correct interpretation of dissolved gas analysis available today. All DGA testing is intended to identify transformers with heat-generating faults that break down the transformer’s internal insulation...
The SorbWeb™ Plus DRH4 Synergy
If you have oil-filled transformers, the law requires you to have a spill prevention plan in place, up to and including a secondary containment system to protect the environment and prevent oil from reaching navigable waters. Albarrie and Voltra Technology have partnered up to provide the power...
The Dissolved Gas Analysis Toolkit
Dissolved gas analysis: addressing the challenges of collecting samples BY DONAL SKELLY, GE’s Digital Energy business Dissolved gas analysis (DGA) is a technique for identifying and quantifying the gas formed in oil-filled electrical equipment because of either the natural aging of oil and paper...
Optimal Transformer Efficiency Using Weighted Average
In order to improve the efficiency of electrical distribution in commercial buildings, the US Department of Energy (DOE) introduced regulations with more stringent minimums on transformer efficiencies in January 2016. This was covered under the Code of Federal Regulations 10 CFR Part 431.192 and...
Cyber Threats on the Rise Invest Now to Boost Power Grid Defenses
Critical infrastructure security is in the national spotlight. In 2020, the power grid and energy sector was the third most targeted sector for cyber-attacks, up from ninth place in 2019, and the threats are growing more sophisticated. The Biden administration recently issued a national security...
Dielectric Voltage Testing – Standard Methods
There are two standard methods from ASTM International: D877, Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes, and D1816, Standard Test Method for Dielectric Breakdown Voltage of Insulating Oils of Petroleum Origin Using VDE Electrodes. VDE stands...
Case Study: Rapid Changes in Bushing Health
IntroductionContinuous online monitoring of bushings provides real-time information which can result in the early detection of a possible failure. Challenge: A Major AlarmA prominent U.S. utility was looking for a way to improve system reliability for their 138kV assets. They researched and...
Hydrogen Monitoring in the Transformer Headspace Compared to Traditional In-Oil Monitoring
By Chris Rutledge, Product Manager, Dynamic Ratings, Inc. Introduction The utilization of online dissolved gas analysis monitoring has proven to be one of the most effective predictors of overall transformer health and condition. A wide range of monitoring systems are available, offering multiple...
The Distribution Transformer - Critical Power System Component
By R.W. Hurst, Editor A distribution transformer is a critical component of the electrical power system, used to reduce the voltage of electrical energy for electric power distribution to end-users. It plays a vital role in voltage regulation and load management, ensuring the efficient and reliable...
Grounding Transformers Explained
By R. W. Hurst, Editor Grounding transformers are used to provide a path to ground for unbalanced load current and for fault currents on systems where a suitable ground is otherwise not available. Grounding transformers are normally constructed with one of the two configurations: Zig-Zag (Zn) with...