Transformer Protection


Prevent Transformer Shutdown

Power transformers seldom shutdown; however, if a shutdown occurs, the effects would be immediate and devastating to utility operations. According to “An Analysis of Transformer Failures” by William H. Bartley, P.E., on behalf of the Hartford Steam Boiler Inspection and Insurance Company, the...

Transformer Monitoring


How to Improve Transformer Protection

Using symmetrical components for fault discrimination in differential protection BY IMRAN RIZVI, ABB Inc. Classical differential protection schemes are subject to ghost differential currents due to current transformer (CT) saturation and magnetization currents. Several methods are used to counter...

Electrical Transformers


Zensol new instrument for OLTC testing

According to CIGRE A2.34, the dynamic resistance measurement or DRM (OFFLINE) is a test that offers diagnostics for several diverter or selector switch malfunctions such as: contact problems, broken springs, broken transition resistors, poor contact pressure, inadequate transition time, momentary...

Transformer Software & Technologies


Dielectric Fluids


New Line of Transformer Oil Exclusively for Canada

This summer, Aevitas Inc. announced a partnership with Calumet Specialty Products Partners, L.P. to bring improved access to premier transformer oil products across Canada. Aevitas will exclusively distribute Calumet’s new line of Caltran™ insulating oil — Caltran C50 — in the Canadian...

Transformer Testing & Maintenance


Radiator Fin(s) Leak Repair

Radiator fins are notorious for leaking at various locations. One of which is where the fins are attached (welded) to the horizontal bottom-run header. Measurements are taken so a weir box can be installed to cover the fin(s) that are leaking. It is preferred the weir box will cover above the...

Power Transformers

hydrocarbon gas emission

Advancements in Dissolved Gas Analysis: CO/CO2 Ratio

For DGA interpretation, faults identified using hydrocarbon gases are considered more serious if they appear to affect paper insulation. That is made explicit in CIGRE technical brochure 771
[1]. Production of hydrocarbon gases from the oil by electrical or thermal stress does not significantly affect the oil’s function as a coolant or electrical insulator. On the other hand, production of carbon oxide gases from paper insulation raises a concern of paper deterioration. In particular, charring...